Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

Reversing, using integrated installation, display, digital current and voltage for three-phase asynchronous motor, the lifting garage door is easy to control the BDK motor and can be operated manually, remote control, at the same time, improve the motor phase, overcurrent protection scheme, simple operation, convenient use, BDK, remote control lifting motor easy to control the inversion, the upper and lower limit for integrated interface, limit switches and other convenient upgrade, up and down, really!

price:USD$540.00
discount 70% in 2018-09-18 to 2018-09-20
price: USD$ 378.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

 

 

 

 

  正反转主机.1

规格分类

特色简介

未标题-1

升降主机易控

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

 

 

This machine adopts the newest microcomputer single chip technology. It has the advantages of being powerful and easy to install and install. The unique current sensing technology and the most simple and reliable control circuit can achieve a full range of motor protection function.
The main functions of the machine: remote control, remote control, automatic learning code, fault cause display, lack of phase protection, overload protection, no load protection, short-circuit protection, manual start / stop, and other functions;
It can be widely used in the control and protection of mixer, electric hoist, elevator and rolling shutter door.

    

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

First, the main technical parameters
1. static power consumption of the host <3W
2. supply voltage: AC380V positive and negative 10%50HZ:
3 remote control frequency: 315M
4. maximum control distance: open theoretical distance 1000M--3000M;
5. decoding: MCU learning decoding (1527 chip)
6. battery voltage: DC9V

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

Two 、 installation guide and main functions

1. basic functions

Main engine installation: open the junction box, connect the power line according to the wiring diagram.
2. boot: switch on the power supply, close the air switch, at this time the screen shows the actual working state
You can press the "forward" key is turning, press the "stop" button to stop, press the "reverse" key inversion, or by remote control
3. setting parameters:

After starting the motor, the current display screen shows the actual working current of the motor: according to the "over-current settings" key
The overload current protection parameter is set to a little larger than the normal working current of the motor: according to the "no load setting" key, the no-load will be unloaded
The current protection parameter is set to less than the normal current of the motor. (set the method see "three")
4. power off prompt:

When the motor is in operation, the current is less than the set "no load" current or the limit switch is disconnected
"Power off" is shown later".
5. phase missing protection:

A sudden interruption of any phase of the three-phase power supply will automatically cut off the power supply within 3 seconds.
6_ overload protection:

When the working current exceeds the set of over-current parameters, the motor will automatically stop: over
The overload current has the characteristics of reverse time overload protection, that is, the more the set value is, the faster the overload protection action is.
7 no load:

When the working current is less than the set of no load current parameters, the motor automatically stops and shows "power off"".
8. short circuit protection:

When the working current is 5 times the current parameter, the machine will automatically run within 0.5 seconds
Stop and short circuit protection can only be restored after power on again.
9. display:

After starting, the display screen shows the actual working current, and without starting, it shows "000"":
Click on any remote key, "signal""The indicator light flashes, indicating the remote pulling function of the building is normal:

10. remote control learning: according to the learning keys can be convenient to code new remote control, but also can remove the old remote control:

 

 

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch







Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

 Two 、 protection function and fault prompt
1. no load current protection:

When the working current of the motor is lower than that of the no-load current parameter, the motor is stopped,The "power off" indicator is always light to indicate no load.
2. overload current protection:

When the working current of the motor exceeds the overload current parameter and stops,The overload indicator is always light to indicate overload:
3. short circuit protection:

After short circuit protection, the "overload" indicator lamp flashes continuously to indicate short circuit.
4. phase missing protection:

The machine is stopped after the lack of phase protection. "Phase missing" light is always on.










   

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

Three. Parameter setting method

1. overload current parameter setting (i.e. current upper limit parameter setting)
This function can be effectively controlled and protected when the motor is blocked, rusted and overloaded. As long as you will
The load current parameter is set to be slightly larger than the motor running current.
Continue pressing the "overload settings" button for 3 seconds to "honk" oneAfter the sound let go, that is, into the current set state, then "too"
"Flow" lights, and digital display of the last set of parameters,Press the "flow settings +" key to increase, and press "no load settings" key to reduce,Adjust the parameters, set up after 15 seconds, automatically save or quit the "stop" button to exit immediately.
The parameters to be set up are: normal running current, overload current parameter, motor overload parameter.

 






Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

2. no load current parameter setting (i.e. "lower limit" protection parameter)
This function controls and protects the limit switch when the contactor is disconnected or has no load, which can prevent the machine from being broken
The control circuit is in the state of energization for a long time. As long as the no-load current parameter is set to less than the motor running time
The current is ok.
Continue to press the "no load" button for 3 seconds to "honk", then let go, that is, into the no load parameter settings. At this point, "missing"
"Water" lights, and digital display of the last set of parameters, according to "over-current settings +" key increase, according to the "no load settings" key to reduceAdjustment of number. After 15 seconds, save or exit by "stop" key
The set parameters should be "idle current < no-load current parameter < normal running current",

   

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

 Three, learning the code function settings
According to the "learning" key 3 seconds to "toot" after a loose, that is, into the study of the code set state, when the display on the ADD, click the remote control of any key "toot" sound that learning success, and even "toot" four soundIndicates that the remote controller has learned: in the learning state, there is no operation in 5 seconds to automatically save or exit
Press "stop" "horse L" to save and exit: one machine can learn more than one remote controller, also can be controlled by a remote controller
Multiple machines.
Remote control method: continue to press the "learning" button 3 seconds to "honk", then let go, and then continue to press""3 seconds, honk 3 sound, eliminate all learning remote control.

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

 2. protection function and fault display

1. no load current protection:

When the working current of the motor is lower than the no-load current parameter, the motor stops,The "power off" indicator is always light to indicate no load.
2. overload current protection:

When the working current of the motor exceeds the overload current parameter and stops,The overload indicator is always light to indicate overload.
3. short circuit protection:

After short circuit protection, the "overload" indicator flashes continuously, indicating short circuit.
4. phase missing protection:

The machine is stopped after the lack of phase protection. "Phase missing" light is always on.

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

3. schematic diagram of basic circuit


Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

Four, matters needing attention
1. "overload current" parameter must be less than "overload current", and "larger than" "normal operation"Otherwise, it will not be effectively protected.
2., the use of air leakage switch must be installed, in order to prevent short circuit or leakage caused by serious safety incidents.
3. when installing wooden products, please operate according to the national standard electrician regulations, please do not live line work, please professional person
Installation to prevent electric shock.
4. if the motor often starts frequently or overload operation, it is necessary to choose the controller larger than the motor,
Otherwise it may burn out the motor or cause an accident.
5, do not install the controller in the wet place, please install in the room, avoids the sunlight direct insolation or the rain.
6. non professionals do not open the host.
7. remote control distance is short or can not remote control, to change the remote control battery.
8. remote control obstacles, the distance will be shorter.
9. when the limit switch is not connected, the control port of "positive turn" and "reverse" must be shorted;
9. regularly check the use and control performance of the controller, in order to prevent accidents.
10. use ambient temperature: 10 to 40C humidity: relative humidity is not greater than 90%
Altitude: no more than 2000M

  

 

Two pumps wireless remote control switch 380V motor positive inversion remote control motor remote control switch

 