C-Lin Xin Ling XMTD-D3001 electronic digital display dial code temperature controller K/E type temperature controller / meter

price:USD$192.00
discount 70% in 2018-09-24 to 2018-09-26
price: USD$ 134.40
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

@vamOXfQlCZJO0I0fOGDxdJ/JBKoSESlYI+oNManGROJTRW3IBJxl+NQdFbx07r1iOuFaRhLymt3OkNv7YYkAl3VamIiA16pTywmUNuwkcPE=@I8H5ZZW2Je6AknOPt/oIkTA/PzwWkP7x@INgBrvwhN3ioWPjvzjhqlg==@

 点这里给我发消息Much点这里给我发消息Small home点这里给我发消息Small high点这里给我发消息Lili点这里给我发消息Customer service  Online time: 08:30AM-23:30PM

 

 

 

 

 

 

 

Intelligent thermostat manual

     Thank you for using the products produced by our factory. The temperature controller produced by our factory has the characteristics of convenient operation, complete function, accurate accuracy and excellent performance. So in use, please carefully read the instructions, in order to understand the correct use of methods, to avoid inconvenience in use.

Function 1: temperature control function (default is temperature control)

1. High temperature start up (refrigeration control):

When the "starting temperature" is greater than "stop temperature", the thermostat is in "high temperature start" state. For example, the actual temperature is 26 degrees, the stop temperature is set to 20 degrees, and the "starting temperature" is set to 26 degrees. When the machine is turned on and the green light is on, the outlet is powered. When the measured temperature is less than or equal to 20 degrees, the standby indicator light is red. At this time, the socket is powered off, and the starting mode is mainly used for cooling, such as opening the air conditioner, exhaust fan and so on.

2. Low temperature starting (heating control):

When the "starting temperature" is smaller than "stop temperature", the thermostat is in "low temperature start" state. For example, the measured temperature is 20 degrees, set the "stop" temperature is 26 degrees, "" the starting temperature of 20 degrees, the green light at the power socket operation instructions, when the measured temperature is greater than or equal to 26 degrees, and the standby indicator light, when the power socket, the start-up mode is mainly used for heating, such as seed germination, pet insulation etc.

Reminder: the default is temperature control. If you need time control, please press the settings button. If not, please don't press the settings button.

Temperature control, please press the starting temperature button and stop button directly.

 

Function two: time control function (press set button, convert to time mode)

1. Clearance time control

"F1" is an intermittent time control mode. (similar to the function of the refrigerator salon), the middle digital tube shows "F1"". The left side of the F1 corresponds to the stop time: press the up and down key (1~99 minutes) to set. The right side of the F1 corresponds to the opening time: press the up and down key (1~99 minutes). As shown above, the left side of the F1 is set "05", and the right side of the F1 is set "10", that is, the stop is 5 minutes and the power is 10 minutes. When the red indicator is on, the green indicator light is on and so on.

2, countdown time control mode

"F2" countdown time control mode. The setting range is between 0001 and 9999 minutes. Left corresponding time: 1~99 settings. Right corresponding time: 1~99 settings. The left corresponds to the thousand bits per hour of the timing. The right corresponding is the ten bit of the timing time. As the figure on the left side of the digital tube is set to "12", the right digital tube is set to "00", then the timing time is 1200 minutes /60, that is 20 hours. Set the time, socket power off, green lights out, red light. The application of timing shutdown, such as electric vehicle timing charging, etc..

3. Reservation time control mode

"F3" appointment time control mode. The setting range is between 0001 and 9999 minutes. Left corresponding time: 1~99 settings. Right corresponding time: 1~99 settings. The left corresponds to the thousand bits per hour of the timing. The right corresponding is the ten bit of the timing time. As the above picture is set for 20 minutes, 20 minutes later, the green indicator lights, and the socket has electricity. Application scope, scheduled appointment boot.

Function three: temperature correction (temperature control error is not large, generally need not be corrected)

Before power on, press and hold the stop temperature and start temperature (add the two buttons on the left and the right) to power up. Then enter the temperature correction setting mode. Digital tube display: --P00--, P00 as the default value, not amended. Then press the stop temperature to increase the correction value (you can see P01, P02, the starting temperature increase) by reduction to reduce the correction value (you can see P-1, P-2 decrease). For example, temperature display temperature is 10 degrees, you feel the temperature is 15 degrees, so the P00 can be adjusted to P05. Then unplug the electricity, re power, the temperature display 15 degrees. If you feel the temperature is 7 degrees, then adjust the P00 to P-3. Then unplug the electricity, re power, the temperature display 7 degrees, and so on.

When the temperature correction is adjusted to the appropriate value, no key operation in 5 seconds, the set value will be automatically saved, then need to re power up to enter the normal workflow.