Factory direct selling XMT-SF503S series economical intelligent temperature controller, temperature control meter, Changchun Sifang instrument

Mail (Gansu, Qinghai, Hainan, Inner Mongolia, Ningxia, Tibet,, Xinjiang), mail only send rhyme or STO, other express need to consult the difference, thank you for your cooperation. (all right to pay)!

price:USD$70.00
discount 70% in 2018-09-23 to 2018-09-25
price: USD$ 49.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

 
  • Summary

 

XMT-SF50S series dual economy type intelligent temperature control instrument is a kind of intelligent industrial high anti-jamming performance, low cost and high reliability of the instrument. The instrument adopts advanced CPU chip, which has the characteristics of simple operation, reliable work and high performance price ratio. It is widely used in the automatic temperature control system of machinery, chemical industry, ceramics, light industry, metallurgy, petrochemical, heat treatment and other industries.

 

  • Main technical indexes

Instrument precision: - 1 DEG C; the cold end compensation error: < - 2 DEG C; power: 220VAC; range: 999 to 9999 DEG C; power: <3W; control mode: a bit control output (to the poor); input mode: thermocouple (K/E/S/B/R/J/T), thermal resistance (Pt100/Cu50) universal input relay output contact capacity: AV220V; resistance load; solid state relay / SCR control output can be selected; working environment: temperature 0 ~ 50 degrees, humidity <85%RH non corrosive non occasions with strong electromagnetic interference.

 

  • Model definition
Model Outline size (mm) Mounting opening dimension (mm) Input type
XMT-SF501S 48×48×70 44+0.5×44+0.5 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
XMT-SF502S 96 X 48 x 70 (vertical) 92+0.7×44+0.5 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
XMT-SF503 48 x 96 x 70 (horizontal) 44+0.5×92+0.7 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
XMT-SF504S 72×72×70 67+0.7×67+0.7 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
XMT-SF505S 96×96×70 92+0.7×92+0.7 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
XMT-SF506S 160 x 80 x 80 (vertical) 152+0.8×76+0.7 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
XMT-SF507S 80 x 160 x 80 (horizontal) 76+0.7×152+0.8 Thermocouple: K/E/S/B/R/J/T thermal resistance: Pt100/Cu50 universal input
  • Panel function

 

  • Instrument wiring terminal (taking the actual instrument wiring diagram as the standard)


XMT-SF504S wiring diagram XMTSF505S wiring diagram
Six. Operation instructions

 

  1. Key definition

① Set) key: A in normal display, pressKey 3 seconds, into the parameter set state;
B in the set state, press onceKey, a new set value of the storage parameter, and the next parameter is displayed.
② (add) key: in the parameter setting state, increase the setting parameter value. In the measurement state, increase the value of control value
③ (reduce) key: in the parameter setting state, reduce the set parameter value. In the measurement state, the control value is reduced
Please press up or down key, you can quickly modify the settings

 

  1. Operation method

The power on self test
Connect the power supply, input and output of the instrument according to the terminal connection of the instrument.
Check the wiring of the instrument carefully, and switch on the power supply before the error is correct.
After the instrument is connected with the power supply, it enters the initial self check state immediately, and enters the measuring state after a few seconds, and then measures it according to the preset parameters in the instrument.
The parameter value set
PressKey, 3 seconds after the instrument into the parameter setting, parameter symbols are displayed in the top display, parameter values in the row display. At this point, you can modify the parameter values by increasing and decreasing the key. You can also pressThe key stores this parameter and does it.
Next parameter setting. Finally, return to the measurement state.

 

Parameter symbol Parameter definition Setting range Notes
SN Input type (this type of instrument is universal input, which can meet the requirements of various types of thermocouple and thermal resistor by setting this parameter) 0-9 0:T(0℃~400℃)   1:R(-0~1000℃)
2:J(0~900℃)    4:B(0~1800℃)
5:S(0~1700℃)       6:K(0~1200℃)   
7:E(0~650℃)     8:PT100(-50~400℃)
9:CU50(-50~150℃)
HR Control mode setting 0、1 0When the parameter is set to 0, the heater is controlled;At this time, the relay action is as follows: when the measured value is less than the control value, the relay is pulled in, and when the measured value is greater than the control value +dF, the relay is disconnected;
1:When the parameter is set to 1, it is used for refrigeration control;At this time, the relay action is as follows: when the measured value is greater than the control value, the relay is pulled in, and when the measured value is less than the control value -dF, the relay is disconnected;
d Return difference 0~9999 When HR = 0, the relay is closed when the measured value is "control value" when the relay is pulled in and the measured value > control value + DF value;
When HR=1, the measured value > control value, the relay is pulled in, and the relay is disconnected when the measured value is "-DF";
SC Correction value of measured value -999~9999 Display value = measurement value +SC normal, SC is set to 0.
DIP Decimal point 0  1 0: no decimal 1: a decimal fraction

 

Seven. Instrument operation
After the instrument is energized, it enters the working state. If you want to set the value, please operate according to the above operation instructions.
Eight, matters needing attention

 

  1. Insert the instrument into the opening of the instrument panel, the opening tolerance should be moderate, install and install the screw, tighten the shell properly, and insert the instrument with self locking into the hole.
  2. Check the instrument number, specification and current and voltage is the same as the instrument.
  3. For thermocouple input signal, please choose the same material as thermocouple compensation wire.
  4. For thermal resistance input signal, please use the same specifications of low resistance wire, and the length of the three lines as much as possible.
  5. Pay special attention to the power input line, the signal input line can not be wrong, and the output terminal is short circuited by strong current, etc..
  6. The power line is separated from the signal line, so as to reduce the influence of electromagnetic radiation on the instrument, and choose the shielding line as far as possible.
  7. Please note: the number of index instrument models with the temperature range and the delivery time of the other special requirements.

8. instrument damage without unpacking, within one year of the manufacturer is responsible for maintenance.