Menu

Connect with us

Shipping large power 10KW three-phase 380V fan culture 220V remote thermostat temperature control switch 650

price:USD$150.00
discount 70% in 2018-09-23 to 2018-09-25
price: USD$ 105.00
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

 Thank you for your attention!

Intelligent temperature controller 380V three-phase power, 220V single-phase electric universal thermostat

 

HS-650 three-phase temperature protection manual

A basic configuration:

1. external power supply: 220VAC, 220VAC/380VAC output control.

2. control objects: a set of output control, maximum power 10KW resistance.

3. temperature display: three digital tube display, a display temperature detection group (hereinafter referred to thermometry) a set of display settings, open (hereinafter referred to a group of open temperature), display off set value (hereinafter referred to Guan Wen).

4. temperature detection: a temperature detection, temperature range: -9~99 DEG (10K3435 thermistor).

Control parameter adjustment range:3~99°

1:High reliability design, the main control chip adopts imported industrial grade PCU, electrical control circuit design is 1/3 higher than the rated power, the 2 completely eliminate the interference caused by the crash, the control circuit and the output pressure bearing failure;

2:Senior safety circuit design -- electricity, electric circuit respectively 2 circuit board design, strong power, weak completely isolated;

3:The use of a machine - heating / cooling mode can be selected for use, can control the heating * heater, hot water circulating pump; cooling can control the ventilation device or refrigeration equipment etc.;

4:Double temperature control settings: open 2 Temperature / temperature shutdown temperature between the distance can be freely set (such as: open the output is not higher than 28 DEG, less than 33 DEG C or less than 9 DEG C open close output output, close the output of more than 47 DEG C, etc.) to avoid the common thermostat and frequent stop ills;

5:The operation is simple and powerful, the temperature value and the temperature difference after the normal use of memory, as long as the "key" on / off;

6:The temperature control of temperature control, timing, timing advance timing closing opening temperature can set an appointment.

 

 

 

 

 Two, the basic functions and parameters:

1. two kinds of heating / cooling temperature control mode can be used with controlled temperature parameters: (default heating mode)

1) model of heating temperature control parameter setting rules: open temperature < off temperature, the temperature rise of lights, namely: low temperature high temperature closed open.

2) cooling mode control parameter setting rules: a temperature value, closing temperature, cooling the lamp, namely: high temperature low temperature start off.

2. heating and cooling temperature control mode of two kinds of operation mode:

1) model of heating operation mode: detection temperature less than open temperature value on output, the temperature detection temperature is more than or equal to shut off output.

2) cooling mode operation mode: detection of temperature is more than or equal to open temperature value on the output, the temperature detection temperature less than shut off output.

3. factory default control parameter: open temperature: 35 degrees, close the temperature: 38 degrees

4. temperature control parameter adjustment range:3~99°

5. limit setting range:30~99 degrees (default 38 degrees, see advanced set 1).

6. infrared remote control:Straight line remote control distance of 15 meters, with a temperature control button function of host, but no press function.

7. long-term temperature control:Press control parameter of long-term operation.

8. timing control:Standby booking open temperature control, temperature control operation can make an appointment to close temperature control.

9. freeze protection:Standby, detection temperature are less than 3 degrees when the road open output of more than 5 DEG C to close the output, output after the opening 10 minutes not stop heating output, then every 10 minutes to open the output of 1 minutes.

10. detection of temperature calibration:If you encounter incorrect measurement according to the actual temperature calibration adjustment of the system (see advanced 2).

11. factory default recovery:If the user makes improper controllers not functioning can be restored to the factory default parameters (see advanced 3).

12. temperature alarm circuit fault:When a temperature sensing circuit or open circuit when the alarm buzzer, the corresponding E1 screen display circuit, resume normal operation.

13. memory:All the parameters of the final set to save memory, running in the power, the power supply was restored according to the state before the power of operation.