Menu

Connect with us

5000W temperature controller, temperature control switch, temperature controller, temperature control switch, electrothermal blanket for electric blanket

price:USD$124.00
discount 70% in 2018-09-19 to 2018-09-21
price: USD$ 86.80
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

Commodity code [YOJdYB7WF1dETSo=]

Product parameter

Operating voltage: 220V/50Hz

Control temperature: 5 - 99 degrees C

Control temperature difference:5——99°C

Rated current: 30A

Maximum load: 5000W

 

1., you can set the starting temperature (5 - 99 degrees C) and stop temperature randomly according to your needs(5——99°C)Automatically open and close the power supply of all kinds of power equipment

2. temperature digital display, intuitive reading, simple operation

3. using a new type of temperature sensor, sensitive response, high accuracy, sensors can be connected according to user needs, without affecting accuracy

Protection function

1.Antifreezing function:When the boiler water drops below 3 degrees centigrade, the circulating pump is forced to start to prevent the pipeline from freezing.
2. Over temperature alarm function:If the water temperature in the system is more than 90 degrees centigrade, the thermostat digital tube flashes and rings, prompting the user to deal with it in time.

Operation method

Due to the heating and cooling of the two needs, so our thermostat also has "high temperature start" and "low temperature start" two modes of operation.

 

1.High temperature startupWhen the "starting temperature" is greater than "stop temperature", the thermostat is in "high temperature start" state. For example: set "stop temperature" is 20 degrees C, "start temperature" is 30 degrees C, then when the measured temperature reaches 30 degrees C, the machine opens, the operation indicator (green light) is bright, at this time the socket power supply. When the actual temperature is reduced to 20 degrees C, the machine is closed, the standby indicator (red light) is bright, and the socket is powered off.
2. Low temperature startingWhen the starting temperature is less than the "stop temperature", the thermostat is in "low temperature start" state. For example: set "stop temperature" is 30 degrees C, "start temperature" is 20 degrees C, then when the measured temperature reaches 20 degrees C, the machine opens, the operation indicator (green light) is bright, at this time the socket power supply. When the measured temperature rises to 30 degrees C, the machine is closed, the standby indicator (red light) is bright, and the socket is powered off.

This paragraph has time control function (switching by middle setting key):

"F1" is an intermittent time control mode. (similar to the function of the refrigerator salon), the middle digital tube shows "F1"". The left side of the F1 corresponds to the stop time: press the up and down key (1~99 minutes) to set. The right side of the F1 corresponds to the opening time: press the up and down key (1~99 minutes). For example, on the left of F1, set "05"","F1" on the right set "10", that is, 5 minutes downtime, boot 10 points. When the red indicator is on, the green indicator light is on and so on.
"F2" countdown time control mode. The setting range is between 0001 and 9999 minutes. Left corresponding time: 1~99 settings. Right corresponding time: 1~99 settings. The left corresponds to the thousand bits per hour of the timing. The right corresponding is the ten bit of the timing time. If the left side of the digital tube is set to "12", the right digital tube is set to "00", then the timing time is 1200 minutes, that is 20 hours. Set the time, socket power off, green lights out, red light. The application of timing shutdown, such as electric vehicle timing charging, etc..
"F3" appointment time control mode. The setting range is between 0001-9999 minutes. Left corresponding time: 1-99 settings. Right corresponding time: 1-99 settings. The left corresponds to a thousand times more than the timing time. The right corresponding is the ten bit of the timing time. Such as set to make an appointment 20 minutes, 20 minutes after the green indicator lights, the machine has power, application scope, scheduled appointment boot.

4. the machine calibration function: press the middle button set, there will be 00 key adjustable calibration temperature according to both sides, assume that the actual temperature is 20 DEG C, such as the right key will display -1, then press the middle button calibration, the actual temperature will jump to 19 degrees, such as the left button will appear again 01. According to the actual temperature calibration button will jump to 21 DEG C.

Set memory function: temperature controller will store your settings, to ensure that the power outage settings will not be lost, no additional settings.

Special note: the temperature control mode and time model of the machine is not used at the same time, the middle of the show when temperature is the temperature control mode, then time control is in the closed state; on the other hand, the middle time display mode (F1F2F3) of any kind, the other time control function is out of the closed state!
Shop for the factory outlets, the sale of control one year warranty, since the delivery receipt within one month of the host and the temperature probe of any quality problems, this shop bear the return freight repair (general area of 10 yuan), the two sides more than a month to repair the main problem to bear the cost of shipping, probe belong to the loss products, and the use of the environment, so it is not in the warranty scope, please note, do not take care!

4B5942A8ED17D8D80CDBBACBF4B0DDA9A1BC83B5EFBAB2815679D87AF4BFD008A7B0E3BA5BF314