Menu

Connect with us

EMC design, test and typical case of switching power supply / Electronic Industry Press

price:USD$55.00
discount 70% in 2018-07-18 to 2018-07-20
price: USD$ 38.50
freight :USD$18.00,(Express)
freight :USD$7.00,(Postal parcel)
views:0
Search Similar or mail to saler or send message to saler

Pay with PayPal, PayPal Credit or any major credit card

  • Revision: 1
  • Page number: 330
  • Number of words: 550000
  • Printing time: 2011-7-1
  • Folio: 16 open
  • Paper: offset paper
  • Impression: 1
  • Packing: paperback
  • Series of books: switching power supply design and production series
  • ISBN ISBN:9787121138942
  • Classification: Books > Industrial Technology > Electrical Technology > independent power supply technology (direct power generation)
    •  

          Content recommendation

          Qian Zhenyu, Shi Jianhua edited the book as the main line to the electromagnetic compatibility of switching power supply, introduces the electromagnetic compatibility test project of switching power supply, switching power supply and related test requirements and test methods, emphatically introduces the electromagnetic compatibility design of switch power supply, the corresponding countermeasures and a typical case of 18. This book strives for practical purposes, in the narration, there are both the disturbance suppression measures which can be taken according to the characteristics of the switching power supply line, and also according to the performance characteristics of a single countermeasure device, to explain its attention should be paid in the use of switching power supply.
          This book is suitable for the circuit design and process design personnel of switching power supply, the system design and research personnel of electronic equipment, as well as the on-site application and maintenance personnel of electronic equipment to read the reference.

          Catalog

          The first chapter is the EMC test standard of switching power supply
          1.1 overview
          Electromagnetic compatibility test requirements of 1.2 switching power supply
          1.3 basic requirements for EMC performance of in machine switching power supply for information technology equipment products
          Test of 1.3.1 electromagnetic disturbance emission
          Measurement of 1.3.2 harmonic current emission
          Test of immunity performance of 1.3.3
          Summary of electromagnetic compatibility test requirements for switching power supply in 1.3.4
          The second chapter is the measurement of electromagnetic disturbance of switching power supply
          Measurement of conducted disturbance of 2.1 AC power line (frequency range 0.15 ~ 30MHz)
          Layout of 2.1.1 test
          2.1.2 measuring receiver
          2.1.3 artificial power network
          2.1.4 test method
          Field intensity measurement of 2.2 radiated disturbance (frequency range 30 ~ 1000MHz)

          The first chapter is the EMC test standard of switching power supply
          1.1 overview
          Electromagnetic compatibility test requirements of 1.2 switching power supply
          1.3 basic requirements for EMC performance of in machine switching power supply for information technology equipment products
          Test of 1.3.1 electromagnetic disturbance emission
          Measurement of 1.3.2 harmonic current emission
          Test of immunity performance of 1.3.3
          Summary of electromagnetic compatibility test requirements for switching power supply in 1.3.4
          The second chapter is the measurement of electromagnetic disturbance of switching power supply
          Measurement of conducted disturbance of 2.1 AC power line (frequency range 0.15 ~ 30MHz)
          Layout of 2.1.1 test
          2.1.2 measuring receiver
          2.1.3 artificial power network
          2.1.4 test method
          Field intensity measurement of 2.2 radiated disturbance (frequency range 30 ~ 1000MHz)
          Layout of 2.2.1 test
          2.2.2 necessary test facilities
          2.2.3 test method
          2.3 measurement of radiation power emission with absorption clamp method (frequency range 30 ~ 300MHz)
          The proposal of 2.3.1 test method
          2.3.2 power absorbing clamp
          2.3.3 measuring lines and instructions
          2.3.4's comment on radiated emission test using absorption clamp method
           ……
          The third chapter: harmonic current emission measurement of switching power supply
          The fourth chapter is the measurement of the immunity of switching power supply
          The fifth chapter qualitative test of electromagnetic disturbance emission of switching power supply
          The sixth chapter is the analysis of the electromagnetic disturbance of the switching power supply, the nature of the disturbance and the overview of the disturbance suppression technology
          The seventh chapter radiated noise of switching power supply and its suppression method
          The ninth chapter is the transient interference suppression of switching power supply
          The tenth chapter design of printed circuit board for switching power supply
          The eleventh chapter: high frequency transformer in switching power supply
          The twelfth chapter is suitable for switching power supply electromagnetic interference suppression chip components
          The thirteenth chapter is the EMC design, test and countermeasure case analysis of switching power supply
          The fourteenth chapter electromagnetic compatibility fault diagnosis and common treatment methods