Model: HCT202T switch sensor

 

Features: monitoringSmall volume, passive.prefix = "o"

 

application area

 

AC current detection

 

State feedback equipment

 

Overcurrent protection device


Electrical parameters

 

       type

parameter

HCT202T

Company

Test conditions

Minimum

typical

Maximum

Input threshold current

(can be customized according to customer requirements)

0.08

0.1

10

Aac

Output sink current

Input current0.5Atime

0.05

1

1000

mA

output voltage

The output current is absorbed5mAtime

0-VCC

0.1-VCC

0.5-VCC

Vdc

response time

threshold0.1A,Input current80mAtime

80

100

200

ms

input overload

input0.5AWhen the maximum overload

5

10

20(1Minute)

A

Input threshold accuracy

Set the current threshold

50

60

70

%

outputCPterminal voltage

Depending on the use of the environment

2

5

24

Vdc

Output AC content

threshold0.1A,input80mA 25C.

3

10

50

mV

temperature coefficient

Set the current threshold

-30℃~85Temperature change60%

Flame retardant grade

UL94V-0

working temperature

-40+85

Storage temperature

-50+90

Resistance    pressure

AC RMS1Minute

3750

4000

5000

Vac

heavy    amount

about10

g

Shell material

PBT Temperature resistance110

 

Matters needing attention

    In Figure 1, figure 2, figure 3 and connecting method 4 must be in use, can not be saved in the R between VCC and CP, such as VCC direct access to the CP end of the switch sensor will cause permanent damage to the device, figure 1, figure 2, figure 3, figure 4 in the R range of R=VCC/IR(IRLess than 1A), in order to save the power consumption, the user can according to their own design to get the value of R, VCC in +224V R, general 1K50K. The best absorption current of 0.25mA100mA, according to the user and.

The use of 4. methods:

When the input current exceeds the set point of protection when the output is low, when the input current is below the current set point protection when the output is +VCC, the R current limiting resistor, when +V=5V R is generally not less than 1K,Figure 1For the test circuit.

 

Application notes:This product is suitable forMonitorThe grid current on the line is overrun, the electric equipment state is advantages of the product in the set range, without any power supply, can be remotely transmitted by the working status of the electric equipment and flow pressure protection switch, can completely replace the current market on the source of the sensor and active isolation module can provide power supply for you to solve the troubles and wiring.